Output peak current(A) | Output RMS current(A) | SW1 | SW2 | SW3 |
1.3 | 0.9 | ON | ON | ON |
1.6 | 1.1 | OFF | ON | ON |
2.1 | 1.5 | ON | OFF | ON |
2.3 | 1.6 | OFF | OFF | ON |
2.5 | 1.7 | ON | ON | ON |
3 | 2.1 | OFF | ON | ON |
3.2 | 2.2 | ON | OFF | ON |
3.5 | 2.5 | OFF | OFF | ON |
4 | 2.8 | ON | ON | OFF |
4.5 | 3.1 | OFF | ON | OFF |
5 | 3.5 | ON | OFF | OFF |
5.3 | 3.8 | OFF | OFF | OFF |
5.8 | 4.1 | ON | ON | OFF |
6.2 | 4.4 | OFF | ON | OFF |
6.5 | 4.6 | ON | OFF | OFF |
7 | 5 | OFF | OFF | OFF |
Current percentage as idle state | SW4 mode |
50% | OFF |
100% | ON |
step/Rev. | SW5 | SW6 | SW7 | SW8 |
400 | ON | ON | ON | ON |
800 | OFF | ON | ON | ON |
1600 | ON | OFF | ON | ON |
3200 | OFF | OFF | ON | ON |
6400 | ON | ON | OFF | ON |
12800 | OFF | ON | OFF | ON |
25600 | ON | OFF | OFF | ON |
51200 | OFF | OFF | OFF | ON |
1000 | ON | ON | ON | OFF |
2000 | OFF | ON | ON | OFF |
4000 | ON | OFF | ON | OFF |
5000 | OFF | OFF | ON | OFF |
8000 | ON | ON | OFF | OFF |
10000 | OFF | ON | OFF | OFF |
20000 | ON | OFF | OFF | OFF |
40000 | OFF | OFF | OFF | OFF |